Why a system can be silent in the laboratory and generate jerking or noise in real application, and which variables are worth measuring.
Stick-slip in plastic components: why motion is not smooth
The component is not broken and wear may still be limited. Yet during movement, it proceeds in small jerks or emits an intermittent noise that makes the product annoying, imprecise, or apparently less robust.
In these cases the main problem is not necessarily material durability. It is the dynamic stability of the interface: the way surfaces transition from adhesion to sliding and maintain motion over time.
What is stick-slip
Stick-slip is a repeated sequence of adhesion and sliding. Surfaces accumulate energy while remaining temporarily “stuck,” then release it when they begin to slide. If this cycle repeats, motion becomes irregular and can generate vibration or noise.
The phenomenon can become critical in guides, actuators, adjustment systems, small mechanisms, automotive interiors, appliances, precision mechanical elements, robotics and mechatronics. Even when it does not immediately compromise component strength, it can reduce precision, perceived quality and functional reliability.
| An average value can hide the problem Two materials can show similar average friction coefficients but have very different start-up transients and stability during sliding. |
Why average coefficient of friction is not enough
To describe stable motion it is useful to distinguish between static friction, dynamic friction and breakaway force. If the force required to start motion is much higher than that needed to maintain it, the system can accumulate and release energy discontinuously.
The trend of force over time also matters. Periodic peaks, oscillations or increasing variations after a certain number of cycles can indicate that the interface is changing due to temperature, wear, transfer film or contamination.
Main causes to verify
1. Surface interactions
Real contact areas are much smaller than the apparent geometric area. At the microscopic level, asperities, local deformations and adhesive phenomena can increase resistance to start-up and make sliding unstable.
2. Roughness and counterpart material
A surface that is too aggressive can increase abrasion; a surface that is too smooth can promote adhesion or unstable lubricating film transfer. Roughness value, surface treatment and counterpart hardness must therefore be part of the tribological requirements gathering.
3. Speed and start-stop cycle
Many stick-slip phenomena emerge at low speeds, during start-up or in intermittent movements. A system that works well in continuous rotation can show very different behavior when motion is short, slow or characterized by frequent reversals.
4. System stiffness and preload
Motion stability also depends on overall mechanics. Structural deformability, clearances, springs, preloads and tolerances influence how much energy can accumulate before contact begins to slide.
5. Temperature
Temperature modifies polymer properties and interface behavior. If noise appears only after a few minutes, or only when cold or at high temperature, this clue should be incorporated into the test plan.
6. Surface evolution
The behavior of the first cycles may not be that at steady-state. Some systems require a run-in phase during which different surface conditions develop. For this reason the test should record not only the final value, but also how friction and noise evolve over time.
From symptom to diagnosis: the questions that really help
- Does noise appear at start-up, during motion or at stop?
- Does it appear immediately or after a defined number of cycles?
- Is it sensitive to temperature or humidity?
- Does it change after cleaning the surfaces?
- Is it present only with a particular counterpart or finish?
- Does noise frequency change with speed?
- Is particulate, transferred film, scratches or shiny areas visible?
A reproducible noise is technical data. Linking it to a specific condition allows building a much more useful test than simply searching for a “more slippery” material.
What role the material can play
A self-lubricating compound can act on start-up resistance, sliding force stability, wear and interface quality. But the formulation must be selected taking side effects into account.
For example, some lubricating systems can promote more regular sliding but have limitations in applications where surface migration, electrical properties or aesthetics are critical. Fibers and reinforcements can improve the structural part but modify contact. The best solution is therefore one that resolves the phenomenon without compromising secondary requirements.
How to set up a stick-slip test
When possible, the test should reproduce real motion and record force as a function of time or position. In addition to average coefficient, it can be useful to observe breakaway force peak, difference between static and dynamic phase, presence of oscillations, temperature and evolution after a significant number of cycles.
- same counterpart or representative material;
- controlled roughness;
- consistent load or pressure;
- realistic speed and acceleration;
- correct motion cycle;
- representative temperature and environment;
- sufficient duration to observe interface evolution.
When material is not the only answer
If noise derives mainly from clearances, resonances, deformations or incorrect preload, changing compound can reduce the symptom without eliminating the cause. For this reason the most effective sequence remains: reproduce the phenomenon, measure it, isolate variables, modify the system and validate the result.
The LATILUB family offers combinations of matrices and self-lubricating systems designed for applications where friction, wear and motion quality must be managed together. The value of application-based selection lies precisely in comparing multiple formulations against the real cycle, instead of optimizing a single datasheet value.
Do you have noise or irregular motion that is difficult to eliminate?
| In the LATI Tribology Design Check you can describe the motion cycle, indicate speed, load, temperature, counterpart material and when the phenomenon appears. A video or recording of the behavior can be particularly useful for setting up a targeted technical evaluation. Discover LATILUB self-lubricating plastic materials |