{"id":15562,"date":"2015-02-25T00:00:00","date_gmt":"2015-02-24T23:00:00","guid":{"rendered":"https:\/\/lati.com\/flame-retardant-compound-for-surge-protection-devices\/"},"modified":"2026-04-13T11:54:19","modified_gmt":"2026-04-13T09:54:19","slug":"flame-retardant-compound-for-surge-protection-devices","status":"publish","type":"post","link":"https:\/\/lati.com\/en\/flame-retardant-compound-for-surge-protection-devices\/","title":{"rendered":"Flame-retardant Compound for Surge Protection Devices"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Electronic Protection and High-Performance Materials<\/h2>\n\n<p class=\"wp-block-paragraph\"><strong>Surge protection devices (SPD)<\/strong> play a crucial role in the safety of electrical installations and lighting systems, preventing damage caused by <strong>voltage spikes<\/strong> due to industrial disturbances or atmospheric discharges.<br\/>In modern LED installations \u2014 such as those for <strong>public, street, or architectural lighting<\/strong> \u2014 the choice of protective materials is essential to ensure <strong>reliability, safety, and durability<\/strong>.<\/p>\n\n<p class=\"wp-block-paragraph\">To meet these needs, the use of a <strong>flame-retardant compound for surge protection devices<\/strong> represents the ideal solution, combining <strong>structural properties, flame retardancy, and environmental sustainability<\/strong>.<\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h2 class=\"wp-block-heading\">Applications in Surge Protection Systems<\/h2>\n\n<p class=\"wp-block-paragraph\">The new <strong>compact SPDs for LED lighting<\/strong> are installed in <strong>control panels and power supplies<\/strong> of small dimensions, where space constraints require components with <strong>high functional density<\/strong>.<br\/>The <strong>thermoplastic compound<\/strong> used in the construction of enclosures and terminal blocks must ensure:<\/p>\n\n<ul class=\"wp-block-list\">\n<li><strong>mechanical and thermal resistance<\/strong>;<\/li>\n\n\n\n<li><strong>dimensional stability<\/strong> over time;<\/li>\n\n\n\n<li><strong>certified flame retardancy<\/strong> according to UL and VDE standards;<\/li>\n\n\n\n<li><strong>absence of halogenated additives or harmful substances<\/strong>.<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">A concrete example is the <strong>PM EP 15 15-275 RES<\/strong> device, which integrates a system for protection against transient overvoltages and lightning in a compact body.<br\/>Its <strong>enclosure and terminal blocks<\/strong> are made of <strong>glass fiber reinforced PA66<\/strong> (25%), a <strong>flame-retardant compound<\/strong> formulated to combine rigidity, flame safety, and sustainability.<\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h2 class=\"wp-block-heading\">Performance of the Flame-Retardant Compound: Technical Requirements<\/h2>\n\n<p class=\"wp-block-paragraph\">The <strong>PA66 V0HF1 compound<\/strong> used for SPDs combines excellent <strong>mechanical and electrical safety properties<\/strong>.<br\/>Thanks to the presence of glass fibers, the material withstands impacts and deformations, maintaining its characteristics even in critical environmental conditions.<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><td><strong>Properties<\/strong><\/td><td><strong>Typical value<\/strong><\/td><td><strong>Reference standard<\/strong><\/td><\/tr><\/thead><tbody><tr><td>Polymer base<\/td><td>PA66 (polyamide 66)<\/td><td>\u2014<\/td><\/tr><tr><td>Glass reinforcement<\/td><td>25%<\/td><td>\u2014<\/td><\/tr><tr><td>Flammability class<\/td><td>UL94 V0<\/td><td>UL 94<\/td><\/tr><tr><td>Glow-wire flammability index (GWFI)<\/td><td>960\u00b0C at 1 mm<\/td><td>IEC 60695-2-12<\/td><\/tr><tr><td>Heat distortion temperature (HDT)<\/td><td>&gt;200\u00b0C<\/td><td>ISO 75<\/td><\/tr><tr><td>Environmental compliance<\/td><td>RoHS, Halogen-Free<\/td><td>\u2014<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\">These characteristics make it suitable for components that must withstand <strong>high temperatures, leakage currents, and ignition risk<\/strong>, such as <strong>connectors, terminal blocks, fuse holders, relays, or protection modules<\/strong>.<\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h2 class=\"wp-block-heading\">Technical Advantages of the Compound for SPD<\/h2>\n\n<p class=\"wp-block-paragraph\">The use of <strong>flame-retardant compounds for surge protection devices<\/strong> ensures:<\/p>\n\n<ul class=\"wp-block-list\">\n<li><strong>Passive protection against fires and short circuits<\/strong>;<\/li>\n\n\n\n<li><strong>Certified electrical safety<\/strong> even in reduced thicknesses;<\/li>\n\n\n\n<li><strong>Excellent processability in injection molding<\/strong>;<\/li>\n\n\n\n<li><strong>Reduction of weight and production costs<\/strong> compared to thermosetting materials;<\/li>\n\n\n\n<li><strong>Environmental compatibility<\/strong>, thanks to the absence of halogens, red phosphorus, and antimony trioxide.<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">These materials meet the reliability requirements demanded by leading manufacturers in the power electronics and electrical protection sector, ensuring a <strong>stable and predictable behavior even in case of overload<\/strong>.<\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h2 class=\"wp-block-heading\">Safety, Sustainability, and Regulatory Compliance<\/h2>\n\n<p class=\"wp-block-paragraph\">The flame-retardant PA66 compound complies with the main <strong>European directives on safety and environment<\/strong>, including:<\/p>\n\n<ul class=\"wp-block-list\">\n<li><strong>RoHS (Restriction of Hazardous Substances)<\/strong>;<\/li>\n\n\n\n<li><strong>REACH (Registration, Evaluation, Authorisation and Restriction of Chemicals)<\/strong>.<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Its <strong>halogen-free<\/strong> formulation ensures an improved ecological profile, avoiding the production of toxic fumes in case of fire and making it suitable for applications in <strong>public and industrial environments<\/strong>.<\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h2 class=\"wp-block-heading\">Conclusions and Employment Prospects<\/h2>\n\n<p class=\"wp-block-paragraph\">The use of <strong>flame-retardant compounds for surge protection devices<\/strong> allows designers to achieve more <strong>secure, compact, and sustainable<\/strong> products.<br\/>The combination of <strong>structural performance, flame resistance, and environmental compliance<\/strong> today represents a technical standard for all components intended for new generation electrical and lighting installations.<\/p>\n\n<p class=\"wp-block-paragraph\"><em>Do you want to delve deeper into the selection of the most suitable flame-retardant compounds for your electronic applications?<\/em><\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/lati.com\/en\/contact-us\/\">Contattaci qui!<\/a><\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h2 class=\"wp-block-heading\">FAQ<\/h2>\n\n<p class=\"wp-block-paragraph\"><strong>1. What does &#8220;flame-retardant compound&#8221; mean?<\/strong><br\/>It is a plastic material that, in case of fire, extinguishes itself without spreading the flame, ensuring safety and protection of equipment.<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>2. What characteristics must a material for SPD devices have?<\/strong><br\/>High mechanical and thermal resistance, certified flame retardancy, dimensional stability, and compliance with RoHS and UL94 V0.<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>3. Why choose a halogen-free compound?<\/strong><br\/>To reduce environmental impact and toxicological risks, improving safety in case of fire or short circuit.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The experience of ABB in the electronics field and LATI&#8217;s expertise in special thermoplastics have led to the creation of a new product dedicated to protection against transient overvoltages and lightning.<\/p>\n","protected":false},"author":1,"featured_media":3217,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"categories":[286,269],"tags":[275],"class_list":["post-15562","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-electrical-electronic","category-flame-retardant","tag-case-study"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Flame-retardant Compound for Protection Devices<\/title>\n<meta name=\"description\" content=\"Discover flame-retardant compounds for SPD: reinforced PA66 materials, halogen-free and UL94 V0 certified for safety in electrical systems.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/lati.com\/en\/flame-retardant-compound-for-surge-protection-devices\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Flame-retardant Compound for Protection Devices\" \/>\n<meta property=\"og:description\" content=\"Discover flame-retardant compounds for SPD: reinforced PA66 materials, halogen-free and UL94 V0 certified for safety in electrical systems.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/lati.com\/en\/flame-retardant-compound-for-surge-protection-devices\/\" \/>\n<meta property=\"og:site_name\" content=\"LATI\" \/>\n<meta property=\"article:published_time\" content=\"2015-02-24T23:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-13T09:54:19+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/lati.com\/wp-content\/uploads\/2025\/04\/i-nuovi-spd-di-abb-la-protezione-da-sovratensioni.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"628\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/lati.com\\\/en\\\/flame-retardant-compound-for-surge-protection-devices\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/lati.com\\\/en\\\/flame-retardant-compound-for-surge-protection-devices\\\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\\\/\\\/lati.com\\\/en\\\/#\\\/schema\\\/person\\\/6e33e609c0315b36e9dceeacb7cbd7ed\"},\"headline\":\"Flame-retardant Compound for Surge Protection Devices\",\"datePublished\":\"2015-02-24T23:00:00+00:00\",\"dateModified\":\"2026-04-13T09:54:19+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/lati.com\\\/en\\\/flame-retardant-compound-for-surge-protection-devices\\\/\"},\"wordCount\":614,\"publisher\":{\"@id\":\"https:\\\/\\\/lati.com\\\/en\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/lati.com\\\/en\\\/flame-retardant-compound-for-surge-protection-devices\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/lati.com\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/i-nuovi-spd-di-abb-la-protezione-da-sovratensioni.jpg\",\"keywords\":[\"Case Study\"],\"articleSection\":[\"Electrical &amp; Electronic\",\"Flame-retardant\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/lati.com\\\/en\\\/flame-retardant-compound-for-surge-protection-devices\\\/\",\"url\":\"https:\\\/\\\/lati.com\\\/en\\\/flame-retardant-compound-for-surge-protection-devices\\\/\",\"name\":\"Flame-retardant Compound for Protection Devices\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/lati.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/lati.com\\\/en\\\/flame-retardant-compound-for-surge-protection-devices\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/lati.com\\\/en\\\/flame-retardant-compound-for-surge-protection-devices\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/lati.com\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/i-nuovi-spd-di-abb-la-protezione-da-sovratensioni.jpg\",\"datePublished\":\"2015-02-24T23:00:00+00:00\",\"dateModified\":\"2026-04-13T09:54:19+00:00\",\"description\":\"Discover flame-retardant compounds for SPD: reinforced PA66 materials, halogen-free and UL94 V0 certified for safety in electrical systems.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/lati.com\\\/en\\\/flame-retardant-compound-for-surge-protection-devices\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/lati.com\\\/en\\\/flame-retardant-compound-for-surge-protection-devices\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/lati.com\\\/en\\\/flame-retardant-compound-for-surge-protection-devices\\\/#primaryimage\",\"url\":\"https:\\\/\\\/lati.com\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/i-nuovi-spd-di-abb-la-protezione-da-sovratensioni.jpg\",\"contentUrl\":\"https:\\\/\\\/lati.com\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/i-nuovi-spd-di-abb-la-protezione-da-sovratensioni.jpg\",\"width\":1200,\"height\":628,\"caption\":\"The new ABB SPDs use high-performance LATI compounds to ensure protection against surges, improving the safety and longevity of electrical installations.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/lati.com\\\/en\\\/flame-retardant-compound-for-surge-protection-devices\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/lati.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Flame-retardant Compound for Surge Protection Devices\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/lati.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/lati.com\\\/en\\\/\",\"name\":\"LATI\",\"description\":\"High Performance Thermoplastics\",\"publisher\":{\"@id\":\"https:\\\/\\\/lati.com\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/lati.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/lati.com\\\/en\\\/#organization\",\"name\":\"LATI Industria Termoplastici S.p.A.\",\"url\":\"https:\\\/\\\/lati.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/lati.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/lati.com\\\/wp-content\\\/uploads\\\/LOGO_RGB.jpg\",\"contentUrl\":\"https:\\\/\\\/lati.com\\\/wp-content\\\/uploads\\\/LOGO_RGB.jpg\",\"width\":1193,\"height\":567,\"caption\":\"LATI Industria Termoplastici S.p.A.\"},\"image\":{\"@id\":\"https:\\\/\\\/lati.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/10320804\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCRHY3BfANQoiMiKcnqoZkjA\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/lati.com\\\/en\\\/#\\\/schema\\\/person\\\/6e33e609c0315b36e9dceeacb7cbd7ed\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/5be589bedeec64f2a523d4e259ffe3e7613cfbdea39bf7c88612b97b67052781?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/5be589bedeec64f2a523d4e259ffe3e7613cfbdea39bf7c88612b97b67052781?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/5be589bedeec64f2a523d4e259ffe3e7613cfbdea39bf7c88612b97b67052781?s=96&d=mm&r=g\",\"caption\":\"admin\"},\"sameAs\":[\"https:\\\/\\\/lati.com\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Flame-retardant Compound for Protection Devices","description":"Discover flame-retardant compounds for SPD: reinforced PA66 materials, halogen-free and UL94 V0 certified for safety in electrical systems.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/lati.com\/en\/flame-retardant-compound-for-surge-protection-devices\/","og_locale":"en_US","og_type":"article","og_title":"Flame-retardant Compound for Protection Devices","og_description":"Discover flame-retardant compounds for SPD: reinforced PA66 materials, halogen-free and UL94 V0 certified for safety in electrical systems.","og_url":"https:\/\/lati.com\/en\/flame-retardant-compound-for-surge-protection-devices\/","og_site_name":"LATI","article_published_time":"2015-02-24T23:00:00+00:00","article_modified_time":"2026-04-13T09:54:19+00:00","og_image":[{"width":1200,"height":628,"url":"https:\/\/lati.com\/wp-content\/uploads\/2025\/04\/i-nuovi-spd-di-abb-la-protezione-da-sovratensioni.jpg","type":"image\/jpeg"}],"author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"admin","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/lati.com\/en\/flame-retardant-compound-for-surge-protection-devices\/#article","isPartOf":{"@id":"https:\/\/lati.com\/en\/flame-retardant-compound-for-surge-protection-devices\/"},"author":{"name":"admin","@id":"https:\/\/lati.com\/en\/#\/schema\/person\/6e33e609c0315b36e9dceeacb7cbd7ed"},"headline":"Flame-retardant Compound for Surge Protection Devices","datePublished":"2015-02-24T23:00:00+00:00","dateModified":"2026-04-13T09:54:19+00:00","mainEntityOfPage":{"@id":"https:\/\/lati.com\/en\/flame-retardant-compound-for-surge-protection-devices\/"},"wordCount":614,"publisher":{"@id":"https:\/\/lati.com\/en\/#organization"},"image":{"@id":"https:\/\/lati.com\/en\/flame-retardant-compound-for-surge-protection-devices\/#primaryimage"},"thumbnailUrl":"https:\/\/lati.com\/wp-content\/uploads\/2025\/04\/i-nuovi-spd-di-abb-la-protezione-da-sovratensioni.jpg","keywords":["Case Study"],"articleSection":["Electrical &amp; Electronic","Flame-retardant"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/lati.com\/en\/flame-retardant-compound-for-surge-protection-devices\/","url":"https:\/\/lati.com\/en\/flame-retardant-compound-for-surge-protection-devices\/","name":"Flame-retardant Compound for Protection Devices","isPartOf":{"@id":"https:\/\/lati.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/lati.com\/en\/flame-retardant-compound-for-surge-protection-devices\/#primaryimage"},"image":{"@id":"https:\/\/lati.com\/en\/flame-retardant-compound-for-surge-protection-devices\/#primaryimage"},"thumbnailUrl":"https:\/\/lati.com\/wp-content\/uploads\/2025\/04\/i-nuovi-spd-di-abb-la-protezione-da-sovratensioni.jpg","datePublished":"2015-02-24T23:00:00+00:00","dateModified":"2026-04-13T09:54:19+00:00","description":"Discover flame-retardant compounds for SPD: reinforced PA66 materials, halogen-free and UL94 V0 certified for safety in electrical systems.","breadcrumb":{"@id":"https:\/\/lati.com\/en\/flame-retardant-compound-for-surge-protection-devices\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/lati.com\/en\/flame-retardant-compound-for-surge-protection-devices\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/lati.com\/en\/flame-retardant-compound-for-surge-protection-devices\/#primaryimage","url":"https:\/\/lati.com\/wp-content\/uploads\/2025\/04\/i-nuovi-spd-di-abb-la-protezione-da-sovratensioni.jpg","contentUrl":"https:\/\/lati.com\/wp-content\/uploads\/2025\/04\/i-nuovi-spd-di-abb-la-protezione-da-sovratensioni.jpg","width":1200,"height":628,"caption":"The new ABB SPDs use high-performance LATI compounds to ensure protection against surges, improving the safety and longevity of electrical installations."},{"@type":"BreadcrumbList","@id":"https:\/\/lati.com\/en\/flame-retardant-compound-for-surge-protection-devices\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/lati.com\/en\/"},{"@type":"ListItem","position":2,"name":"Flame-retardant Compound for Surge Protection Devices"}]},{"@type":"WebSite","@id":"https:\/\/lati.com\/en\/#website","url":"https:\/\/lati.com\/en\/","name":"LATI","description":"High Performance Thermoplastics","publisher":{"@id":"https:\/\/lati.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/lati.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/lati.com\/en\/#organization","name":"LATI Industria Termoplastici S.p.A.","url":"https:\/\/lati.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/lati.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/lati.com\/wp-content\/uploads\/LOGO_RGB.jpg","contentUrl":"https:\/\/lati.com\/wp-content\/uploads\/LOGO_RGB.jpg","width":1193,"height":567,"caption":"LATI Industria Termoplastici S.p.A."},"image":{"@id":"https:\/\/lati.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/10320804","https:\/\/www.youtube.com\/channel\/UCRHY3BfANQoiMiKcnqoZkjA"]},{"@type":"Person","@id":"https:\/\/lati.com\/en\/#\/schema\/person\/6e33e609c0315b36e9dceeacb7cbd7ed","name":"admin","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/5be589bedeec64f2a523d4e259ffe3e7613cfbdea39bf7c88612b97b67052781?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/5be589bedeec64f2a523d4e259ffe3e7613cfbdea39bf7c88612b97b67052781?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/5be589bedeec64f2a523d4e259ffe3e7613cfbdea39bf7c88612b97b67052781?s=96&d=mm&r=g","caption":"admin"},"sameAs":["https:\/\/lati.com"]}]}},"_links":{"self":[{"href":"https:\/\/lati.com\/en\/wp-json\/wp\/v2\/posts\/15562","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lati.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/lati.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/lati.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/lati.com\/en\/wp-json\/wp\/v2\/comments?post=15562"}],"version-history":[{"count":2,"href":"https:\/\/lati.com\/en\/wp-json\/wp\/v2\/posts\/15562\/revisions"}],"predecessor-version":[{"id":29689,"href":"https:\/\/lati.com\/en\/wp-json\/wp\/v2\/posts\/15562\/revisions\/29689"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/lati.com\/en\/wp-json\/wp\/v2\/media\/3217"}],"wp:attachment":[{"href":"https:\/\/lati.com\/en\/wp-json\/wp\/v2\/media?parent=15562"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/lati.com\/en\/wp-json\/wp\/v2\/categories?post=15562"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/lati.com\/en\/wp-json\/wp\/v2\/tags?post=15562"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}